RS485 PM2.5/PM10 Sensor Modbus Particle Detection Sensor Transmitter Air Quality Detection
RS485 PM2.5/PM10 Sensor Modbus Particle Detection Sensor Transmitter Air Quality Detection
1. PM2.5, PM10 output at the same time
485 communication (modbus) protocol baud rate: 2400.4800 (default) .9600
Data bit length: 8 bits
Parity mode: none
Stop bit length: 1 bit
Default modbus communication address: 1
Support function code: 03Parameter settings: Configured with the supplied configuration software via the 485 interface
Wiring instructions
Cable color | Description | |
Power | Brown | Power+ (10-30vdc ) |
black | Power - | |
Communication | yellow | 485-A |
Blue | 485-B |
Communication protocol
Basic communication parameters
Code | 8-bit binary |
Data bit | 8 bit |
Parity bit | NO |
Stop bit | 1 bit |
Error check | CRC |
Baud rate | 2400bit/s, 4800bit/s, 9600 bit/s default is 4800bit/S |
4.2 Data frame format definition
Adopt Modbus-RTU communication protocol, the format is as follows:
Initial structure ≥ 4 bytes of time
Address code = 1 byte
Noise Transmitter Instruction Manual (Type 485) V2.0
Function code = 1 byte
Data area = N bytes
Error check = 16-bit CRC code
End structure ≥ 4 bytes of time
Address code: is the address of the transmitter, which is unique in the communication network (factory default 0x01).
Function code: The instruction function of the command sent by the host. This transmitter only uses function code 0x03 (read register data).
Data area: The data area is the specific communication data. Note that the 16bits data high byte is in front!
CRC code: Two-byte check code.
Host inquiry frame structure:
Address code | Function code | Register start address | Register length | check code low | Check code high |
1 bytes | 1 bytes | 2 bytes | 2 bytes | 1 bytes | 1 bytes |
Slave transponder frame structure
Address code | Function code | effective byte | No 1 Data area | NO2 Data area | No N Data area | Check code |
1 bytes | 1 bytes | 1 bytes | 2 bytes | 2 bytes | 2 bytes | 2 bytes |
Register address
Register address | PLC or configuration address | content | operation |
0000 H | 40001 | PM2.5 Upload data is the real value | Read only |
0000 H | 40002 | PM10 Upload data is the real value | Read only |
4.4 Communication protocol examples and explanations
Example: Read the PM value of device address 0x01
Inquiry frame:
Address code | Function code | Start address | Data length | check code low | Check code high |
0x01 | 0x03 | 0x00 0x00 | 0x00 0x02 | 0xC4 | 0x0B |
Response frame: (eg read 85ug/m3 for PM2.5 and 156ug/m3 for PM10)
Address code | Function code | effective byte | humidity | temperature | check code low | Check code high |
0x01 | 0x03 | 0x04 | 0x00 0x55 | 0x00 0x9c | 0xEA | 0x4A |
PM2.5 calculation:
Air quality (PM2.5/P10) transmitter instruction manual (type 485) V2.0
PM2.5:0055 H (hexadecimal) = 85=> PM2.5 = 85ug/m3
PM10 calculation:
PM10:009CH (hexadecimal) = 156 => PM10 = 156ug/m3
Package includes:

(1) FREE Shipping 10 - 15 business days, (2) Standard Shipping 7 - 12 business days.
Shipping and Delivery Estimates
We ship in-stock orders as soon as possible. This is often within two business days, but there are situations where it may take longer. All estimates are based on business days.
Note:
(1) The shipping time mentioned above refers to the estimated time of business days that the shipment will take after an order has been shipped.
(2) Business days do not include Saturday/Sunday and any public holidays.
(3) These estimates are based on normal circumstances and are not a guarantee of delivery times.
(4) We are not responsible for the failures or delays in delivery resulting from any force majeure event, such as natural disaster, bad weather, war, customs issues, and any other event beyond our direct control.
Our policy lasts 14 days. If 14 days have gone by since your purchase, unfortunately we can't offer you a refund or exchange. To be eligible for a return, your item must be unused and in the same condition that you received it. It must also be in the original packaging.
for more information please visit our Refunds & Returns Policy page.