Overview:
 
1.We provide the software to connect it with the PC. If you want to connect it with other terminal device such as PLC, and so on, please prepare the fitable cable and write the program by yourself.
2. This document describes the specification of the PZEM-004T AC communication module, the module is mainly used for measuring AC voltage, current, active power, frequency, power factor and active energy, the module is without display function, the data is read through the TTL interface.
 
PZEM-004T-10A: Measuring Range 10A (Built-in Shunt)
PZEM-004T-100A: Measuring Range 100A (external transformer)
 
If you need the software, please download it via this link:
 
 
Specifications:
 
Working voltage: 80 ~ 260VAC
Test voltage: 80 ~ 260VAC
Rated power: 100A/22000W
Operating frequency: 45-65Hz
Measurement accuracy: 1.0 grade
 
Function:
 
Voltage
1.1.1        Measuring range:80  260V
1.1.2        Resolution: 0.1V
1.1.3        Measurement accuracy: 0.5%
1.2   Current
1.2.1        Measuring range: 0  - 10A(PZEM-004T-10A); 0 - 100A(PZEM-004T-100A)
1.2.2        Starting measure current: 0.01A(PZEM-004T-10A); 0.02A(PZEM-004T-100A)
1.2.3        Resolution: 0.001A
1.2.4        Measurement accuracy: 0.5%
1.3   Active power
1.3.1        Measuring range: 0 - 2.3kW(PZEM-004T-10A); 0 - 23kW(PZEM-004T-100A)
1.3.2        Starting measure power: 0.4W
1.3.3        Resolution: 0.1W
1.3.4        Display format:
<1000W, it display one decimal, such as: 999.9W
≥1000W, it display only integer, such as: 1000W
1.3.5        Measurement accuracy: 0.5%
1.4   Power factor
1.4.1        Measuring range: 0.00 - 1.00
1.4.2        Resolution: 0.01
1.4.3        Measurement accuracy: 1%
1.5   Frequency
1.5.1        Measuring range: 45Hz - 65Hz
1.5.2        Resolution: 0.1Hz
1.5.3        Measurement accuracy: 0.5%
1.6   Active energy
1.6.1        Measuring range: 0 - 9999.99kWh
1.6.2        Resolution: 1Wh
1.6.3        Measurement accuracy: 0.5%
1.6.4        Display format:
<10kWh, the display unit is Wh(1kWh=1000Wh), such as: 9999Wh
≥10kWh, the display unit is kWh, such as: 9999.99kWh
1.6.5        Reset energy: use software to reset.
1.7   Over power alarm
Active power threshold can be set, when the measured active power exceeds the threshold, it can alarm
1.8   Communication interface
RS485 interface
 
Communication protocol
 
1.1   Physical layer protocol
Physical layer use UART to TTL communication interface
Baud rate is 9600, 8 data bits, 1 stop bit, no parity
 
Package Included:
 
1 x  PZEM-004T TTL Modbus-RTU Power Voltmeter Ammeter
 
 









Additional Information
Color1

#3, #4, #5, #6, #1, #2

Shipping information

(1) FREE Shipping 10 - 15 business days, (2) Standard Shipping 7 - 12 business days.

Shipping and Delivery Estimates

We ship in-stock orders as soon as possible. This is often within two business days, but there are situations where it may take longer. All estimates are based on business days.

Note:

(1) The shipping time mentioned above refers to the estimated time of business days that the shipment will take after an order has been shipped.

(2) Business days do not include Saturday/Sunday and any public holidays.

(3) These estimates are based on normal circumstances and are not a guarantee of delivery times.

(4) We are not responsible for the failures or delays in delivery resulting from any force majeure event, such as natural disaster, bad weather, war, customs issues, and any other event beyond our direct control.

Return and exchanges

Our policy lasts 14 days. If 14 days have gone by since your purchase, unfortunately we can't offer you a refund or exchange. To be eligible for a return, your item must be unused and in the same condition that you received it. It must also be in the original packaging.

for more information please visit our Refunds & Returns Policy page.